VEEVÕTUKOHTADE PROJEKTEERIMINE
We offer a comprehensive solution for the design, testing, and documentation of firefighting water supply points – including dry hydrants.
In the course of our work, we follow the requirements of the following legal acts and standards:
-
Regulation No. 4 of the Minister of Economic Affairs and Infrastructure, dated 17 January 2024 – Requirements for ensuring firefighting water supply
-
Regulation No. 8 of the Minister of the Interior, dated 23 February 2021 – Procedure for the use and inspection of firefighting water intake
-
EVS 812-6:2012/A2:2017 – Firefighting water supply. Part 6: Water intake points
2.
Analysis and submission of documentation
3.
Testing and inspection, as well as ongoing support during the usage permit procedure
4.
Kontrollime valminud veevõtukoha ja teeme vajalikud toimingud kasutusloamenetluses




What does the water intake design service include?
• Analysis and consultation of water intake options for the site
• Preparation of the project with a site plan, technical solutions and explanatory memorandum
• Preparation and submission of a construction notice in the construction register
• Testing and inspection of fire water intake points (including access, marking, water volume)
• Support for the operating permit procedure after successful testing and completion of documents
Dry hydrant - standard solution
Nowadays, it is no longer possible or reasonable to plan the classic direct water intake from a water body - therefore, dry hydrants are used as the main solution in scattered settlements and new housing areas.
Our selection includes a dry hydrant DN200, which is suitable for the banks of water bodies and reservoirs, meets the connection requirements of rescue equipment, and can be designed and installed according to the EVS 812-6 standard.
We install with marking, testing and all necessary documentation.
Additional service: analytical assessment and water transport calculation
If desired, we additionally offer:
• Assessment of the suitability of a fire water intake point
• Preparing a water transport calculation (e.g. remote water intake or shared access)
• Preparation of risk analysis and justified exception for the Rescue Board or local government
If you need a competent partner in designing, inspecting, or processing documents for a water intake point, we will help you quickly and correctly.
We ensure that your property meets fire safety requirements – efficiently, legally, and professionally.

Tuleohutusteenuste juht
Ardon Kaerma
Eesti üks esimesi TASE 6 tuleohutuseksperte.
-
Tuleohutusekspert, tase 6
Kutsetunnistus 166218 -
Turvasüsteemide projekteerija, tase 6
Kutsetunnistus 223445
-
Eesti päästemeeskonna EDRT liige
-
Eesti päästemeeskonna EST-USAR liige Türgis, Hatay provintsis aastal 2023
TULIPUNANE OÜ: reliable and experienced partner in fire safety
Tulipunane OÜ is a company based on private capital that has been offering fire safety services since 2012. Our main field of activity is the development of various fire safety solutions in the design and construction phase.
Our strength is experienced specialists in the field of fire safety, who find a reasonable solution even in the most difficult situation.
Sobivad tooted meie tootevalikust Tuleohutuskaubamajas:
FIRE SAFETY SERVICES & TRAINING
Our experienced specialists will help you in every matter related to fire safety - be it fire safety consultation for construction projects, various fire safety expertise, fire safety audit, smoke removal design or applying for a use permit.
EXPERTISE
Expertise on solid fuel heating systems , construction project expertise, building expertise - we perform various expertise related to fire safety.