top of page
IMG_4269.jpeg

VEEVÕTUKOHTADE PROJEKTEERIMINE

We offer a comprehensive solution for the design, testing, and documentation of firefighting water supply points – including dry hydrants.

In the course of our work, we follow the requirements of the following legal acts and standards:

  1. Regulation No. 4 of the Minister of Economic Affairs and Infrastructure, dated 17 January 2024 – Requirements for ensuring firefighting water supply

  2. Regulation No. 8 of the Minister of the Interior, dated 23 February 2021 – Procedure for the use and inspection of firefighting water intake

  3. EVS 812-6:2012/A2:2017 – Firefighting water supply. Part 6: Water intake points

2. 

Analysis and submission of documentation

3. 

Testing and inspection, as well as ongoing support during the usage permit procedure

IMG_0761.jpeg
IMG_4265.jpeg
IMG_4269.jpeg
IMG_0758.jpeg

What does the water intake design service include?


• Analysis and consultation of water intake options for the site
• Preparation of the project with a site plan, technical solutions and explanatory memorandum
• Preparation and submission of a construction notice in the construction register
• Testing and inspection of fire water intake points (including access, marking, water volume)
• Support for the operating permit procedure after successful testing and completion of documents

 

 

Dry hydrant - standard solution


Nowadays, it is no longer possible or reasonable to plan the classic direct water intake from a water body - therefore, dry hydrants are used as the main solution in scattered settlements and new housing areas.

Our selection includes a dry hydrant DN200, which is suitable for the banks of water bodies and reservoirs, meets the connection requirements of rescue equipment, and can be designed and installed according to the EVS 812-6 standard.
We install with marking, testing and all necessary documentation.

 

 

Additional service: analytical assessment and water transport calculation


If desired, we additionally offer:
• Assessment of the suitability of a fire water intake point
• Preparing a water transport calculation (e.g. remote water intake or shared access)
• Preparation of risk analysis and justified exception for the Rescue Board or local government

If you need a competent partner in designing, inspecting, or processing documents for a water intake point, we will help you quickly and correctly.
We ensure that your property meets fire safety requirements – efficiently, legally, and professionally.

Ardon Kaerma Tulipunane OÜ.jpg

Ardon Kaerma

Security systems designer, LEVEL 6

Professional certificate 223445

Fire safety expert LEVEL 6

Professional certificate 127932

FIRE SAFETY SERVICES & TRAINING

Our experienced specialists will help you in every matter related to fire safety - be it fire safety consultation for construction projects, various fire safety expertise, fire safety audit, smoke removal design or applying for a use permit.

FIRE SAFETY AUDIT

Construction fire safety audit, fire safety audit of construction projects, fire safety audit of public events.

SMOKE REMOVAL

Planning and design of smoke extraction systems and smoke control.

TRAININGS & EXERCISES

We offer various fire safety training and exercises.

EXPERTISE

Expertise on solid fuel heating systems , construction project expertise, building expertise - we perform various expertise related to fire safety.

LICENSE

Checking documentation, completing missing documents, administration and application.

FIRE SAFETY INSPECTION

Fire safety consultation for construction projects, 192€/h

DESIGNING

Fire safety section of the preliminary design, fire safety section of the main design and fire safety section of the detailed design, evacuation simulation and

Structural simulation

CONSTRUCTION PROJECT CONSULTATION

Fire safety consultation for construction projects, 192€/h

Tulipunane OÜ's expertise and audits are protected by architect/engineer liability insurance!

Activity licenses of the Economic Activity Register:

FOT000009 - Fire safety service

FPR000620 - Smoke extraction design

FKH000243 - Inspection and maintenance of fire extinguishers

© 2019 Tulipunane OÜ. 

portrait_b.png
EAS+logo-+horizont.jpg

Tallinn office

Suure Patarei 2
10415, Tallinn

Kuressaare office

Kuressaare Edukontor
Tallinna 1, 93819, Kuressaare

CONSULTATION TIME MUST BE BOOKED IN ADVANCE:

info@tulipunane.ee

Phone: +372 620 0542​

  • LinkedIn Social Icon
  • Facebook Social Icon
bottom of page